GENERATING SET ->Diesel
Air
Cooled-> Single Phase
->
2.2 to 7.5 KVA |
|
ENGINE |
Cooling |
Air
(Radial) |
No.
of Cyl. |
One |
Fuel |
H.S.
Diesel |
Type |
Vertical ,4-stroke,compression
ignition |
Speed |
1500/1800 RPM |
Starting |
Handle start
(Optional-Electrical) |
Fuel tank |
5 to10
liters |
A. C.
GENERATOR |
Voltage |
230/415 V |
Phase |
Single/Three |
Frequency |
50
Hz |
Regulation |
± 5
% Max. |
Insulation |
F
Class |
|
Single cylinder Air Cooled
Generator |
Technical
Specification
Model |
AC Generators ( Alternator ) |
Diesel Engine |
Dry
Weight
(Kg) |
Rated Output |
No.
of
Phase |
Current
(Amps) |
Power
Factor |
Rated Power
(HP) |
KVA |
KW |
CAS 200
|
2.0 |
2.0 |
ONE |
8.7 |
1.0
(UPF) |
4.0 |
145 |
CAS
300
|
3.0 |
3.0 |
ONE |
13.0 |
1.0
(UPF) |
6.25 |
255 |
CAS
400
|
4.0 |
4.0 |
ONE |
17.4 |
1.0
(UPF) |
7.0 |
275 |
CAS 500
|
5.0 |
5.0 |
ONE |
21.7 |
1.0
(UPF) |
9.0
|
295 |
CAS 600
|
6.0 |
6.0
|
ONE |
26.1 |
1.0
(UPF) |
11.0
|
305 |
|
|
|
|
|
GENERATING SET ->Diesel
Air
Cooled-> Single Phase
->
8 to 12 KVA |
|
ENGINE |
Cooling |
Air
(Radial) |
No.
of Cyl. |
Two |
Fuel |
H.S.
Diesel |
Type |
Vertical ,4-stroke,compression
ignition |
Speed |
1500
RPM |
Starting |
Handle start
(Optional-Electrical) |
Fuel tank |
10 to20
liters |
A. C.
GENERATOR |
Voltage |
230/415 V |
Phase |
Single/Three |
Frequency |
50
Hz |
Regulation |
± 5
% Max. |
Insulation |
F
Class |
|
Double cylinder Air Cooled
Generator |
Technical
Specification
Genset
Model |
AC Generators ( Alternator ) |
Diesel Engine |
Dry
Weight
(Kg) |
Rated Output |
NO.
Of
Phase |
Rated
Current
(Amps) |
Power
Factor |
Rated Power
(HP) |
KVA |
KW |
CAS 800
|
8.0 |
8.0 |
ONE |
34.8 |
1.0
(UPF) |
14.0 |
410 |
CAS
1000
|
10.0 |
10.0 |
ONE |
43.5 |
1.0
(UPF) |
16.0 |
420 |
CAS
1200
|
12.0 |
12.0 |
ONE |
52.2 |
1.0
(UPF) |
20.0 |
47 |
|
|
|
|
|
GENERATING SET ->Diesel
Air
Cooled-> Three Phase
->
5 to 8.7 KVA |
|
ENGINE |
Cooling |
Air
(Radial) |
No.
of Cyl. |
One |
Fuel |
H.S.
Diesel |
Type |
Vertical ,4-stroke,compression
ignition |
Speed |
1500/1800 RPM |
Starting |
Handle start
(Optional-Electrical) |
Fuel tank |
5 to10
liters |
A. C.
GENERATOR |
Voltage |
230/415 V |
Phase |
Single/Three |
Frequency |
50
Hz |
Regulation |
± 5
% Max. |
Insulation |
F
Class |
|
Single cylinder Air Cooled
Generator |
Technical
Specification
Model |
AC Generators ( Alternator ) |
Diesel Engine |
Dry
Weight
(Kg) |
Rated Output |
No. of
Phase |
Current
(Amps) |
Power
Factor |
Rated Power
(HP) |
KVA |
KW |
CAT 500
|
5.0 |
4.0
|
THREE
|
7.0 |
0.8
(LAG) |
6.25 |
270 |
CAT 625
|
6.25 |
5.0 |
THREE
|
8.7 |
0.8
(LAG) |
7.0 |
275 |
CAT 750
|
7.5 |
6.0 |
THREE
|
10.4 |
0.8
(LAG) |
9.0 |
285 |
CAT
870 |
8.7 |
7.0 |
THREE
|
12.2 |
0.8
(LAG) |
11.0 |
305 |
|
|
|
|
|
GENERATING SET ->Diesel
Air
Cooled-> Three Phase
->
10 to 15 KVA |
|
ENGINE |
Cooling |
Air
(Radial) |
No.
of Cyl. |
Two |
Fuel |
H.S.
Diesel |
Type |
Vertical ,4-stroke,compression
ignition |
Speed |
1500
RPM |
Starting |
Handle start
(Optional-Electrical) |
Fuel tank |
10 to20
liters |
A. C.
GENERATOR |
Voltage |
230/415 V |
Phase |
Single/Three |
Frequency |
50
Hz |
Regulation |
± 5
% Max. |
Insulation |
F
Class |
|
Double cylinder Air Cooled
Generator |
Technical
Specification
Genset
Model |
AC Generators ( Alternator ) |
Diesel Engine |
Dry
Weight
(Kg) |
Rated Output |
No.
of
Phase |
Rated
Current
(Amps) |
Power
Factor |
Rated Power
(HP) |
KVA |
KW |
CAT 1000
|
10.0 |
8.0 |
THREE
|
13.9 |
0.8
(LAG) |
14.0 |
430 |
CAT
1250 |
12.5 |
10.0 |
THREE
|
17.4 |
0.8
(LAG) |
16.0 |
440 |
CAT 1500
|
15.0 |
12.0 |
THREE
|
20.8 |
0.8
(LAG) |
20.0 |
465 |
|
|
|
|
GENERATING SET ->
Gas Water Cooled
->
15.0 to 82.5 KVA |
|
ENGINE |
Cooling |
Water |
No.of cyl. |
2 , 3, 4 &
6 |
Fuel |
L. P. Gas, Natural Gas, Propane, Bio
Gases |
Speed |
1500/1800 RPM |
Type |
Vertical
,4-stroke |
Spark Ignition |
Starting |
Electrical(12
Volts) |
Governor |
Mechanical | |
A. C.
GENERATOR |
Voltage |
230/415 V |
Phase |
Single/Three |
Frequency |
50/60 Hz |
Insulation |
F
Class |
Mounting |
Foot |
Power Factor |
0.8 |
|
Gas Genset CNG
60 |
Technical
Specification
Genset
Model |
AC Generators |
Diesel Engine |
Rated Output |
Rated Current (Amps)
|
Rated
Power
|
No.
of
Cylinders |
Swept
Volume
(cc) |
Aspiration |
Fuel Consumption at 75% rated
power |
KVA |
KW |
Three Phase |
Single Phase |
hp |
kW |
Natural
Gas
Scum/Hr |
L.P.Gas
Kg/Hr |
CNG 15
|
15 |
12 |
21 |
63 |
20 |
14.7 |
2 |
2376 |
Natural |
3.6 |
2.4 |
CNG 25
|
25 |
20 |
35 |
105 |
32 |
23.5 |
3 |
3307 |
Natural |
5.7 |
3.8 |
CNG 40
|
40 |
32 |
56 |
168 |
50 |
36.8 |
4 |
4561 |
Natural |
8.8 |
5.9 |
CNG 65
|
60 |
48 |
83 |
NA |
75 |
55.2 |
4 |
4561 |
Turbo Charged |
12.5 |
8.3 |
CNG 82
|
82.5 |
66 |
115 |
NA |
105 |
77.3 |
6 |
6614 |
Turbo Charged |
17.0 |
11.3 |
|
*Fuel consumption purely depends on the composition of gaseous
fuel. Contact for further details on other gases and
applications. |
|
|
|
Back to Top |